Customer is adding a new bathroom on the 28th floor that will require a single wall mount strobe to meet fire code.[CF 10/15/2026 - This permit was not needed. Bathroom already has a strobe installed in ACT ceiling. Contractor on site requests to close this permit.] · Electrical
No product keyword matched · Seattle electrical permits
25th floor mechanical room has 4-5 fire alarm field devices that need to be relocated in the same room temporarily while un-related boiler equipment repair / replacement takes place.
Fire system will be fully functional upon departure at all phases. · Electrical
No product keyword matched · Seattle electrical permits
Temporarily remove and then reinstall upon completion of the remodel work, one (1) speaker strobe on level 39 just inside the occupied space. · Electrical
No product keyword matched · Seattle electrical permits
To upgrade the existing Notifier NFS2-3030 fire alarm control panel with the direct replacement Notifier N16X with integrated digital voice and smoke control capabilities. The replacement is necessary due to the existing failing audio message generator of the current system. The existing FACP location in Fire Room 104 on the main level will be re-used as depicted on this submittal. All other existing field devices and wiring will be connected to the new FACP. The existing sequence of operation · Electrical
No product keyword matched · Seattle electrical permits
Update of notification appliances on level 5 associated with the tenant improvement project as noted within the area of work on the drawings.1 existing strobe will be removed, 1 existing speaker strobe will be removed, 1 strobe appliance will be added, 2 strobe appliances will be replaced, and 10 speaker strobes will be replaced. The net effect of this scope of work will reduce the circuit current draw and voltage drop of the existing circuits to be modified. As such, the existing back-up batte · Electrical
No product keyword matched · Seattle electrical permits
As part of recent demolition and new wall installation, two wall-mounted fire device will need to be reinstalled. Previously wall-mounted devices will need to be reinstalled; however, they now need to be swapped to acoustic ceiling-mounted devices. · Electrical
No product keyword matched · Seattle electrical permits
As part of the tenant improvement to renovate suites on level 39 through level 42 of the building, the fire alarm system notification appliances will be updated in the area of work. The existing speaker circuit on each level will be used for the new appliances with new cable to be installed for the area of work. A new power supply will be installed next to the existing power supply on level 39. New cable will be installed for the fire alarm visual circuits serving all areas of work. (2) new mec · Electrical
No product keyword matched · Seattle electrical permits
Complete replacement and upgrade of the head-end fire alarm control panel. This replacement is necessary due to the aging condition of the current system. · Electrical
No product keyword matched · Seattle electrical permits
Level 38 renovation of suites. Fire alarm system notification appliances will be updated in the area of work. Existing speaker circuit on level 38 will be used for the new appliances with new cable to be installed. A new power supply will be installed to replace the existing power supply on level 38. New cable will be installed for the fire alarm visual circuits serving the area of work. · Electrical
No product keyword matched · Seattle electrical permits
TENANT IMPROVEMENT TO EXISTING FIRE ALARM SYSTEM IN EXISTING BUILDING. NEW PULL STATIONS AT EXITS, DUCT DETECTION SUPERVISION, & OCCUPANT NOTIFICATION · Electrical
No product keyword matched · Seattle electrical permits
REPLACE FACP WITH SILENT KNIGHT 6700, ADD CLSS FOR MONITORING, REPLACE MINI-HORNS IN BEDROOMS WITH LOW FREQUENCY SOUNDERS, SWAPPING OUT DEVICES AND USING EXSITING WIRE · Electrical
No product keyword matched · Seattle electrical permits