Installed new range outlet and breaker on existing wiring
Installed new dishwasher outlet on existing wiring
Installed new disposal outlet on existing wiring
Relocated existing wiring for light over sink and under cabinet lights · Electrical
Installed new range outlet and breaker on existing wiring
Installed new dishwasher outlet on existing wiring
Installed new disposal outlet on existing wiring
Relocated existing wiring for light over sink and under cabinet lights · Electrical
No product keyword matched · Seattle electrical permits
Installation of a 200 amp meter main with breaker space with a 2 inch overhead riser
Installation of a new 200 amp feeder from the 200 amp meter main to the new 200 amp main breaker electrical panel
Installation of a new grounding electrode system with ground rods and added hold home surge protectionprotection device.
Installation of a dedicated 20 amp bidet receptacle in the upstairs bathroom and a 240 V 1000 W cadet heater install installed in the upstairs bathroom with a wall thermostat · Electrical
No product keyword matched · Seattle electrical permits
Installation of a whole panel surge protection device tied in with the 30 amp hot water tank
circuit.
Repaired and protected the hot water heater by replacing the ungrounded metal box and adding
1/2in metal flex conduit. · Electrical
No product keyword matched · Seattle electrical permits
Install an 80a feeder to the new Sub- Panel in the basement
Install 5 dedicated circuits
- 1xGarage receptacles
- 2x 20a circuits for the basement fridge and freezer
- 1x Basement receptacles
- 1x Basement lighting
Install a whole Panel Surge protector on the main electrical panel · Electrical
No product keyword matched · Seattle electrical permits
STE 100
Extend existing receptacle circuit and install new receptacle in the maintenance space between
the floors. This is done on the downstairs area above the hallway ceiling
Install conduit for low-voltage contractor for data systems by both front doors and the bathroom
entry hallway · Electrical
No product keyword matched · Seattle electrical permits
Relocation of the 40 EV charging circuit. We will be moving the outlet up and install an EV rated receptacle and we will be installing a two pole 40 amp GFCI circuit breaker. · Electrical
No product keyword matched · Seattle electrical permits
* installation of a new 15 amp dedicated circuit to the garbage disposal
We will be running the circuit in the existing half inch EMT conduit coming out of the back of the
panel, running along the side of the home and then 90s with a LB connector over to a
weatherproof box where it then penetrates into the building and feeds the dishwasher
receptacle. We will be coming into the box that has the dishwasher and running a flex extension
over to a new four square metal box where we will install the · Electrical
No product keyword matched · Seattle electrical permits
Add subpanel to existing panel
Add whole panel surge protection to existing panel and new subpanel
Replace miscellaneous devices in home and add arc fault protection to circuits worked on
Add dedicated circuit and dining room area for Insta hot appliance · Electrical
No product keyword matched · Seattle electrical permits
UNIT #1600
Replace the Outlet under the sink serving the Dishwasher and Disposal. Add Afci/Gfci 20a
breaker for the dishwasher and disposal ircuit · Electrical
No product keyword matched · Seattle electrical permits