Plumbing Permit · Repair of improperly installed gas line at meter. Meter pulled and capped. Extension of gas line to new connection point with pressure test. Work to be completed prior to meter reinstallation by utility.
Plumbing Permit · Repair of improperly installed gas line at meter. Meter pulled and capped. Extension of gas line to new connection point with pressure test. Work to be completed prior to meter reinstallation by utility.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Replacement of existing exterior grease interceptor with a new 1000-gallon City of Austin approved unit in the same location. Like-for-like replacement no re-routing or extension of pipelines and no change to fixture count. Performed under Austin Water Industrial Waste Approval No. 2026-079402-00. Existing interceptor failed Austin Water inspection on 8/11/2025; replacement required by 8/11/2026.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Repair backflow according to code tested for leaks and verified to be operating properly. After installation the backflow will be tested to ensure proper function. The price includes the required city permit.
located in the mechanical room Bldng B
model Wilkins 975XL
Serial #888053
The process water failed when tested 3/4-1 Complete Repair Kit
No product keyword matched · Austin issued construction permits
Plumbing Permit · Repair backflow preventer. The backflow will be repaired according to code tested for leaks and verified to be operating properly. After repair of the backflow will be tested to ensure proper function. The price includes the required city permit.
Backflow failed when tested located on the right side under the sink of the break room ice maker.
Model # 007-QT serial 80609 Watts 007 1/2 .
Backflow failed when tested located on the left side Replaced with Watts Model # 007QT Serial #09346 1/2
Located under the sink left side ice maker in the break room
No product keyword matched · Austin issued construction permits
Plumbing Permit · Repaired back flow preventer when tested it failed. The repair will be according to code tested for leaks and verified to be operating properly. After the repair of the backflow it will be tested to ensure proper function. The price includes the required city permit.
Suite 220 model # 008QT Serial #47099 Repair 008 Watts 3/8-1/2 TTL Repair Kit
Repair of backflow Make Watts 3 Model #008QT Serial #47099 Repair kit 008 watts 3/8-1/2 TTL
Pedicure Bowel on the left wall.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Located on the left side of the Building
W will remove a 3x3 access to the affected area. The dept of the leak is 5 ft down.
We will replace 4 cast iron line with 40 PVC approximately 20-25 ft and using hangers every 4-5 ft.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Cut and remove 4x4 section of concrete in front of the retaining wall in the South Hallway of building 3 to access and make the repair of a cracked pipe beneath the slab
No product keyword matched · Austin issued construction permits