Plumbing Permit · retroactive permit application for the emergency replacement of two (2) existing 100-gallon commercial water heaters serving the apartment building.
At the time of the original service call the existing water heaters were actively leaking and the building had been without hot water for approximately seven business days. Due to the active leaks and lack of domestic hot water to the building the condition was classified as an emergency and replacement work proceeded immediately.
Magic Plumbing ATX sourced and replaced both existing 100-gallon water heaters and replaced/repaired associated damaged piping and components within the mechanical room as required to complete the installation and restore hot water service.
During the work extremely heavy scale/mineral buildup was observed on the hot-water side of the existing system and piping.
This application is being submitted retroactively to permit and inspect the completed emergency water-heater replacement work.
Plumbing Permit · retroactive permit application for the emergency replacement of two (2) existing 100-gallon commercial water heaters serving the apartment building.
At the time of the original service call the existing water heaters were actively leaking and the building had been without hot water for approximately seven business days. Due to the active leaks and lack of domestic hot water to the building the condition was classified as an emergency and replacement work proceeded immediately.
Magic Plumbing ATX sourced and replaced both existing 100-gallon water heaters and replaced/repaired associated damaged piping and components within the mechanical room as required to complete the installation and restore hot water service.
During the work extremely heavy scale/mineral buildup was observed on the hot-water side of the existing system and piping.
This application is being submitted retroactively to permit and inspect the completed emergency water-heater replacement work.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Renovation to existing condo unit in MF building combining two units unto one. SPE approved to reduce the unit count. Master Plumber and Master Electrician have signed the A sheets for minor Electrical and Plumbing work.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Magic Plumbing ATX / Magic Mechanical LLC will remove existing grease interceptors and install new 1000-gallon traffic-rated grease interceptors at the approved project locations.
Work includes:
811 utility locates prior to excavation.
Pumping and cleaning existing grease interceptors.
Excavation to expose and remove existing grease interceptors.
Disposal of existing grease interceptors in accordance with applicable regulations.
Preparation and compaction of subgrade for new installation.
Installation of new 1000-gallon traffic-rated grease interceptors.
Installation of new inlet and outlet sanitary sewer piping.
Installation of new cleanouts and required inspection manholes.
Connection of grease interceptor to existing sanitary sewer system.
Bedding backfill and compaction around new installation.
Leak testing and inspection of installed piping.
Restoration of trench areas to a safe condition pending final surface restoration.
Coordination of all required plumbing inspections with the City of Austin.
All work to be performed in accordance with the currently adopted City of Austin Plumbing Code International Plumbing Code (IPC) as adopted and all applicable local regulations.
Project Location(s)
4961 W US Highway 290 Austin TX
1418 E. Anderson Lane Austin TX 78752
10203 Lake Creek Parkway Austin TX
Work Description
Commercial plumbing work consisting of the replacement of existing grease interceptors with new traffic-rated 1000-gallon grease interceptors including associated excavation sanitary sewer piping modifications cleanouts inspection manholes testing and inspection.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Installing a tench drain to collect water used to clean dog grooming area. The trench drain will tie into an existing drain inside the facility. A new canopy is proposed to provide coverage over the area draining into the trench.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Existing mercantile facility for delivery operation. Scope of work is limited to the interior modification to approximately 500 SF of the existing single story retail storage area to provide an accessory commercial coffee kitchen. Renovation includes new equipment minor framing plumbing mechanical and electrical work.
No product keyword matched · Austin issued construction permits
Plumbing Permit · Commercial plumbing permit application for replacement of existing exterior grease interceptor at existing Wendys quick-service restaurant facility. Scope includes removal and replacement of existing grease interceptor with new 1000-gallon exterior grease interceptor reconnecting existing grease waste piping and associated plumbing connections in compliance with current UPC and Austin Water requirements. Existing fixture load and grease waste calculations based on existing conditions report.
No product keyword matched · Austin issued construction permits
Plumbing · Existing dentist office plumbing to be removed. new ADA bathroom and relocation of existing sanitary & storm risers and replace associated in-slab piping per plans. Application filed in conjunction with M01276888-I1 (GC) & M01276888-S1 (MS)
No product keyword matched · NYC DOB building permits